PowerStore: "Appliance port pairs are connected to the same data switch" error when multiple independent iSCSI switches are used

Summary: This article discusses the PowerStore Alert "Appliance port pairs are connected to the same switch:%(connection_scheme). The article examines the use case when a customer has decided to setup the PowerStore appliance with independent iSCSI switches. This configuration is referred to as "L2 uplinks without MC-LAG" in the Dell EMC PowerStore - Networking Guide for PowerStore T Models. ...

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

The PowerStore OS may generate alerts when multiple independent iSCSI switches are used. 

Cause

The PowerStore Operating System (OS) has a subsystem called ONV (Ongoing Network Validation).  ONV is designed to identify configurations which may not be optimal. Some valid configurations may generate false positive warnings.

The PowerStore storage networks generally involve pairs of Ethernet switches for iSCSI connectivity with some form of inter-switch link (ISL) between them. In this configuration, Storage networks typically span both switches through the ISL. Corresponding ports from each PowerStore node connect to a different switch. For example, I/O Card 1 port 2 on node A and I/O Card 1 port 2 on node B (known collectively as a ‘Port Pair’) go to two different switches. This gives each port pair redundancy for switch/cable failure.
Figure 1: Storage networks with connected switches

 
Some customers prefer to have independent iSCSI switches (with no ISLs) for their storage networks. Without ISLs, VLANs cannot span the two switches – each switch runs its own subnet. The PowerStore assigns storage networks by port pair across nodes, so this method requires the same port from each node to be connected to the same switch. The first switch would be connected to one port pair, and the second switch connects to a different port pair on the appliance. When cabled in this manner the ONV detects that a single port pair has no redundancy at a switch level and generates a warning, even though the overall configuration is fully redundant.
 
Figure 2: Storage networks with independent switches
 

Resolution

The warnings generated by the PowerStore ONV subsystem do not necessarily mean there is anything wrong with the configuration, nor does it mean this configuration does not follow best practices.

As long as there are two switches with two storage networks connected, and each host has a connection to both storage networks, the cluster can operate without interruption through a single failure (such as a switch). In this configuration, the warnings may be safely ignored. When these warnings are ignored, care should be taken to ensure the configuration really is fully redundant.

Affected Products

PowerStore, PowerStore 1000X, PowerStore 1000T, PowerStore 3000X, PowerStore 3000T, PowerStore 5000X, PowerStore 5000T, PowerStore 500T, PowerStore 7000X, PowerStore 7000T