This article applies to PowerVault ME5012 or ME5024 arrays with a single controller configuration.
If an administrator tries to change default management IP address (10.xx.xx.x) of a ME5 single controller system using PowerVault Manager (see attached screenshot), the "Set IPV4" button does not activate.
Trying a different web browser or clearing web browser cache has no effect on the issue.
This issue affects PowerVault systems with controller firmware version, ME5.1.0.0.0, and will be addressed in a future firmware release.
# set network-parameters ip 192.xxx.xx.x netmask 255.xxx.xxx.xxx gateway 192.xxx.xx.x controller a
# set network-parameters ip 192.xxx.xx.x netmask 255.xxx.xxx.xxx gateway 192.xxx.xx.x controller b