A execução de um PUHC no Unity OE 5.1 ou código posterior pode falhar com o erro:
check_if_user_root_fs_has_enough_space_1
No primary_sp/nas/log/check_health.<data>.log arquivo, há dois erros conhecidos:
1) host desconhecido:
Data Movers: Check if user root fs has enough space Command failed: * Command: /nas/bin/.server_config nas server -v "df" * Command output: Error 4023: nas : unknown host * Command exit code: 2 Action : Escalate this issue through your support organization. Provide this output in the escalation. ERROR_CODE=dm::check_if_user_root_fs_has_enough_space_1|Error|/nas/bin/.server_config nas server -v "df"|Error 4023: nas : unknown host |2
2) Erro de análise XML:
-------------------------------------Errors------------------------------------- Data Movers: Check if user root fs has enough space Command failed: * Command: /nas/bin/.server_config MMCSMKPACS -v "df" * Command output: MMCSMKPACS : commands processed: 1 Action : Escalate this issue through your support organization. Provide this output in the escalation. ERROR_CODE=dm::check_if_user_root_fs_has_enough_space_1|Error|/nas/bin/.server_config nasserver -v "df"|nasserver : commands processed: 1 <<< XML parsing error: EOF looking for CDATA section end [Ln: 99, Col: 15] XML::Simple called at /nas/lib/DartCmd.pm line 366. for the document: <?xml version="1.0"?> <MAC_RESPONSE ID="client: 1" REQUEST_ID="1"> <MAC_COMMAND_RESPONSE COMMAND_ID="1" VDM="3"> <CFGCMD COMMAND="df"> <RAW_OUTPUT>
XML parsing error: EOF looking for CDATA section end [Ln: 99, Col: 15] A CDATA section starts with "<![CDATA[" and ends with "]]>". <![CDATA[......]]> Looks like CDATA EOF parsing issue.
No exemplo acima, o nome do servidor NAS "servidor nas" é inválido e causará falha na verificação de integridade pré-upgrade. Renomeie o servidor NAS para remover o caractere de espaço inválido e execute novamente a verificação de integridade pré-upgrade.
Se o problema ainda persistir após renomear o servidor NAS, abra um caso de suporte e consulte este artigo da KB.