Pokyny

A global hot spare is an unused disk that is part of the disk group. Hot spares remain in standby mode. When a hard drive that is used in a virtual disk fails, the assigned hot spare is activated to replace the failed hard drive without interrupting the system or requiring your intervention. When a hot spare is activated, it rebuilds the data for all redundant virtual disks that were using the failed hard drive.

You can change the hot spare assignment by unassigning a disk and choosing another disk as needed. You can also assign more than one hard drive as a global hot spare.

To assign or unassign a global hot spare for a hard drive, complete the following steps:
Does my controller support this feature? See Supported Features.


Using the PERC HII Configuration Utility

Perform the following steps to create global hot spares:

  1. Press F2 during server POST to enter System Setup.
  2. Select Device Settings.
  3. Select the PERC controller from the list of devices to enter the PERC configuration Utility.
  4. Click Main Menu > Physical Disk Management.
    The list of physical disks is displayed.
  5. Select the physical disk.
  6. From the Operations drop-down menu, select Assign Global Hot Spare.
  7. Click Go.
    A screen is displayed asking if you are sure you want to perform the operation.
  8. Select the Confirm option.
  9. Click Yes.
    The global hot spare disk is created successfully.

Using OpenManage Server Administrator

  1. Select the disk in the Connector (channel or port) table that you want to use as the dedicated hot spare. On some controllers, more than one disk can be selected. The disks that you have selected as dedicated hot spares are displayed in the Disks that are configured as a dedicated hot spare table.
  2. Click Apply Changes when ready.
Note: To replace a failed hard drive, global hot spares must use the same disk technology and must be equal or greater in size.

Using iDRAC8

  1. In the iDRAC Web interface, go to the menu Overview > Storage > Physical Disks > Setup. The Setup Physical Disk page is displayed.
  2. From the Controller drop-down menu, select the controller to view the associated hard drives.
  3. To assign as a global hot spare, from the drop-down menus in the Action-Assign to All column, select Global Hotspare for one or more hard drives.
  4. To unassign a hot spare, from the drop-down menus in the Action-Assign to All column, select Unassign Hotspare for one or more hard drives.
  5. From the Apply Operation Mode drop-down menu, select when you want to apply the settings.
  6. Click Apply

Using iDRAC9

  1. In the iDRAC web interface, go to Configuration > Storage Configuration.
    The Storage Configuration page is displayed
    In iDRAC 5.10.00.00 and later, click the Storage tab.

  2. In versions prior to iDRAC 5.10.00.00, From the Controller drop-down menu, select the controller to view the associated hard drives.

  3. Click Physical Disk Configuration.
    All the hard drives associated to the controller are displayed.
    In iDRAC 5.10.00.00 and later, click on Physical Disk.

  4. To assign as a global hotspare, from the drop-down menus in the Action column, select Assign Global Hotspare for one or more hard drives.

  5. To unassign a hot spare, from the drop-down menus in the Action column, select Unassign Hotspare for one or more hard drives.

  6. Click Apply Now.
    Depending on your requirement, you can also choose to apply At Next Reboot or At Scheduled Time. The settings are applied based on the selected operation mode.

 


Další informace

Please refer to this video:

Dotčené produkty

PowerEdge RAID Controller H345, PowerEdge RAID Controller H350 Adapter SAS, PowerEdge RAID Controller H355 Front SAS, PowerEdge RAID Controller H355 Adapter SAS, PowerEdge RAID Controller H730P MX, PowerEdge RAID Controller H745 , PowerEdge RAID Controller H745P MX, PowerEdge RAID Controller H750 Adapter SAS, PowerEdge RAID Controller H755 Adapter, PowerEdge RAID Controller H755 MX Adapter, PowerEdge RAID Controller H755N Front NVMe, PowerEdge RAID Controller H755 Front SAS, PowerEdge RAID Controller H965i Adapter, PowerEdge RAID Controller H965i Front, PowerEdge RAID Controller H965i MX, PowerEdge RAID Controller H730, PowerEdge RAID Controller H730P, PowerEdge RAID Controller H740P, PowerEdge RAID Controller H840, PowerEdge RAID Controller H965e Adapter ...

Produkty

PowerEdge C4130, PowerEdge c6320, PowerEdge c6320p, PowerEdge C6420, PowerEdge C6520, PowerEdge C6525, PowerEdge C6615, PowerEdge C6620, PowerEdge M640, PowerEdge M640 (for PE VRTX), PowerEdge MX750c, PowerEdge MX760c, PowerEdge R240, PowerEdge R250 , PowerEdge R260, PowerEdge R340, PowerEdge R350, PowerEdge R360, PowerEdge R440, PowerEdge R450, PowerEdge R540, PowerEdge R550, PowerEdge R640, PowerEdge R6415, PowerEdge R650, PowerEdge R650xs, PowerEdge R6515, PowerEdge R6525, PowerEdge R660, PowerEdge R660xs, PowerEdge R6615, PowerEdge R6625, PowerEdge R740, PowerEdge R740XD, PowerEdge R740XD2, PowerEdge R7415, PowerEdge R7425, PowerEdge R750, PowerEdge R750XA, PowerEdge R750xs, PowerEdge R7515, PowerEdge R7525, PowerEdge R760, PowerEdge R760XA, PowerEdge R760xd2, PowerEdge R760xs, PowerEdge R7615, PowerEdge R7625, PowerEdge R840, PowerEdge R860, PowerEdge R940, PowerEdge R940xa, PowerEdge R960, PowerEdge T150, PowerEdge T160, PowerEdge T340, PowerEdge T350, PowerEdge T360, PowerEdge T440, PowerEdge T550, PowerEdge T560, PowerEdge T640 ...
Vlastnosti článku
Číslo článku: 000178190
Typ článku: How To
Poslední úprava: 08 lis 2024
Verze:  8
Najděte odpovědi na své otázky od ostatních uživatelů společnosti Dell
Služby podpory
Zkontrolujte, zda se na vaše zařízení vztahují služby podpory.