Connectrix MDS: SFP shows as "in sync state" when the link is down
Summary: SFP shows as "in sync state" when the link is down.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
An SFP is installed on a port but in a down link state. View the output from the below command:
`show interface brief` ----------------------------------------------------------------------------------------- Interface Vsan Admin Admin Status SFP Oper Oper Port Logical Mode Trunk Mode Speed Channel Type Mode (Gbps) ----------------------------------------------------------------------------------------- fc1/16 11 auto on notConnected swl -- -- -- --
It displays as "in sync state" when viewed with the below command for the interface details:
No tx fault, rx loss, in sync state, diagnostic monitoring type is 0x68
Cause
This is a cosmetic issue and is identified in the Cisco Issue CSCwa49621 .
The SFP sync state for 16 Gbps ports should be ignored in affected Cisco NX-OS releases. This applies to all Cisco NX-OS releases but only for 16 Gbps ports.
Resolution
Resolution:
The issue is known and addressed in Release: 9.3(1)
The issue is known and addressed in Release: 9.3(1)
Affected Products
Connectrix MDS-Series FirmwareArticle Properties