Connectrix MDS: SFP shows as "in sync state" when the link is down

Summary: SFP shows as "in sync state" when the link is down.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

An SFP is installed on a port but in a down link state. View the output from the below command:   
`show interface brief`
-----------------------------------------------------------------------------------------
Interface  Vsan   Admin  Admin   Status       SFP    Oper  Oper   Port     Logical
                  Mode   Trunk                       Mode  Speed  Channel   Type
                         Mode                              (Gbps)
-----------------------------------------------------------------------------------------    
fc1/16      11     auto   on      notConnected swl    --    --     --       --       

It displays as "in sync state" when viewed with the below command for the interface details:

No tx fault, rx loss, in sync state, diagnostic monitoring type is 0x68

Cause

This is a cosmetic issue and is identified in the Cisco Issue CSCwa49621 This hyperlink is taking you to a website outside of Dell Technologies..

The SFP sync state for 16 Gbps ports should be ignored in affected Cisco NX-OS releases. This applies to all Cisco NX-OS releases but only for 16 Gbps ports. 

Resolution

Resolution:
The issue is known and addressed in Release: 9.3(1)

Affected Products

Connectrix MDS-Series Firmware
Article Properties
Article Number: 000216220
Article Type: Solution
Last Modified: 18 Apr 2025