Symptoms
he VxRail Cluster upgrade was progressing and out of four nodes, one node was completed. While upgrading the second node, the upgrade script reported an error
Failure occurred while running an upgrade for bundle: VXRAIL_COMPOSITE-7.0.451-28053212_for_7.0.x.zip. The error message: Failure occurred while scheduling firmware. The error message: FAILURE..
Cause
There are stale entries in the iDRAC.
Resolution
To clear the stale entries, reboot the iDRAC on the VxRail node and restart the upgrade.
Steps:
1. Login to the iDRAC page for the node when the cluster reported the issue.
2. Navigate to Maintenance
3. Click on Diagnostics and reboot iDRAC.
4. Wait for 10 minutes and restart the upgrade from the VxRail page.
This is a temporary workaround to get the upgrade complete. As a best practice from support, It is better to reboot the nodes and reboot of the iDRAC's before starting the upgrade.
Affected Products
VxRail, VxRail 460 and 470 Nodes, VxRail Appliance Family, VxRail Appliance Series, VxRail D560, VxRail D560F, VxRail E Series Nodes, VxRail E460, VxRail E560, VxRail E560 VCF
Products
VxRail E560F, VxRail E560F VCF, VxRail E560N, VxRail E560N VCF, VxRail P470, VxRail P570, VxRail P570 VCF, VxRail P570F, VxRail P570F VCF, VxRail P580N, VxRail S Series Nodes