PowerMax: Health Check in Embedded Unisphere is Failing with "The request to run config changes failed"

Summary: Health check in Embedded Unisphere 9.2.3.22 is failing with "Config change. The request to run config changes failed, see the SYMAPI logs for more information."

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

  • Ran Health check from the backend, it came clean. There were no hardware failures or failed scripts.
  • Deleted failed health checks in Job list and tried running the HC in Unisphere, still it failed with the below error.

  Config Change Error

 

From SYMAPI logs:

07/04/2023 06:13:26.414  30549       run health check;
07/04/2023 06:13:26.414  30549     }
07/04/2023 06:13:28.830  30549     Initiating COMMIT of maintenance changes................Queued.
07/04/2023 06:13:29.849  30549    155 EMC:UNIVMAX                cfgLogSymmwinError   SymConfigChangeControl call to cfgControlPoll for Polling failed with code: SWRS_ERR
07/04/2023 06:13:29.854  30549     SID 00019790XXXX:     Script handling returned sts code 0x23: Message 0x00000023
SwProc.exe failed.
07/04/2023 06:13:29.856  30549     SID 00019790XXXX: API msg : The Configuration Server failed to complete the operation. Please examine the SYMAPI log file for details
07/04/2023 06:13:29.856  30549     COMMIT monitoring failed
07/04/2023 06:13:31.552  30549     Terminating session with configuration server.............Done.
07/04/2023 06:14:03.864  30549    156 EMC:UNIVMAX                iSymConfigChangeSess Starting a local Maintenance session for SID 00019790XXXX, symapi V9.2-2637 (3.6) ucode 5978
07/04/2023 06:14:04.155  30549     Establishing session with Local cfg srvr (00019790XXXX)...Established.
07/04/2023 06:14:04.155  30549     Session ID   16811264 (0x01008500)
07/04/2023 06:14:04.259  30549    156 EMC:UNIVMAX                iSymConfigChangeCont iSymConfigChangeControl: session_id = 1
07/04/2023 06:14:04.264  30549     {
07/04/2023 06:14:04.264  30549       run health check;
07/04/2023 06:14:04.264  30549     }
07/04/2023 06:14:06.660  30549     Initiating COMMIT of maintenance changes................Queued.
07/04/2023 06:14:07.635  30549    156 EMC:UNIVMAX                cfgLogSymmwinError   SymConfigChangeControl call to cfgControlPoll for Polling failed with code: SWRS_ERR
07/04/2023 06:14:07.640  30549     SID 00019790XXXX:     Script handling returned sts code 0x23: Message 0x00000023
SwProc.exe failed.
07/04/2023 06:14:07.640  30549     SID 00019790XXXX: API msg : The Configuration Server failed to complete the operation. Please examine the SYMAPI log file for details

 

Cause

Unknown

 

Resolution

  1. Reboot MMCS
  2. Delete the failed Health check tasks in the Job list and refresh the Unisphere.
  3. Re-run Health check in Unisphere.

 