請勿在更新 BIOS 時將電腦關機或拔除電源,電腦可能因此受損。更新期間,電腦將重新啟動,並且會暫時顯示黑色畫面。

更新前,請閱讀以下所述的安裝說明與重要資訊。

Dell EMC Server PowerEdge BIOS M640/FC640/M640 VRTX Version 1.3.7

需要重新啟動 已自動安裝 此檔案會在最近更新時自動安裝。如果您遇到任何問題,可以手動下載並重新安裝。
此頁面的內容可能經過電腦自動翻譯。若要提供意見回饋,請填寫頁面底部的表單。
This release contains new Intel Xeon Processor Scalable Family Processor Microcode to address CVE-2017-5715. CVE-2017-5753 and CVE-2017-5754 do not require a microcode update. This release fixes Intel Management Engine issue that causes first BIOS flash update attempt to fail after 24 days of server up-time. This release contains BIOS firmware version 1.3.7 for Dell EMC Server PowerEdge M640/FC640/M640 VRTX.
建議

為您的系統尋找最適合的下載項目

請輸入產品的詳細資料以檢視系統的最新驅動程式資訊

搜尋支援

輸入您的 Dell 產品服務編號或型號

想要尋找您的產品嗎?請輸入產品識別碼。 告訴我怎麼做

此驅動程式不相容

此驅動程式不適用於選取的產品。請選擇其他產品,以重新輸入適用於此驅動程式的產品詳細資料,或前往產品支援頁面,檢視其他產品的所有驅動程式。

尋找更多更新。使用 SupportAssist 為您的裝置尋找所有最新的驅動程式更新。

修復及強化

Fixes
- BIOS takes a long time to handle correctable memory errors.
- Several NVMe-related defects.
- Intel Management Engine issue that causes first BIOS flash update attempt to fail after 24 days of server up-time.
- Fix does not take effect until after flashing this BIOS.
- See PSQN SLN309027 for complete detail - http://www.dell.com/support/article/us/en/04/SLN309027

Enhancements
- Updated the Intel Trusted Execution Technology (Intel TXT) BIOS Authenticated Code Module (ACM) to version 1.3.4.
- Updated the Intel Processor and Memory Reference Code to PLR3.1.
- To address CVE-2017-5715 (http://www.cve.mitre.org/cgi-bin/cvename.cgi?name=2017-5715):
- Updated the Intel Xeon Processor Scalable Family Processor Microcode to version 0x43.
- CVE-2017-5753 and CVE-2017-5754 are addressed by the Operating System & Hypervisor updates.
- For more information, visit http://www.dell.com/support/article/SLN308588
閱讀更多

繁體中文版

1.3.7, 1.3.7

發佈日期

18 2月 2018

下載類型

系統 BIOS

類別

BIOS

重要性

緊急
Dell Technologies 強烈建議儘快套用此重要更新。此更新包含的重大錯誤修正和變更,可改善 Dell 系統功能、可靠性及穩定性。其也可能包含安全性修正和其他增強功能。
可用的格式 檢視重要資訊

檔案格式: 適用於 MS Windows (64 位元) 的更新套件。
檔案名稱: BIOS_XRN29_WN64_1.3.7.EXE
檔案大小: 26.13 MB
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
如果 Dell 更新套件為原生 Microsoft Windows 64 位元格式,則不需要在 Microsoft Windows Server 安裝 Microsoft WOW64。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
2fa51a3f3830a0f31811bde2b9c69cdf
SHA1:
678a63a649e1c9d572ad56f9a3854ca5614973ed
SHA-256:
ec0085eb2274324a191623e71bcc0b26ae706609cc3a65791d794dc58335f1e8

檔案格式: 包含密碼編譯簽章的 GnuPG 檔案
檔案名稱: BIOS_XRN29_LN_1.3.7.BIN.sign
檔案大小: 226 Bytes
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
您可以使用適用於 Red Hat Linux 更新套件的 GnuPG 簽章,在相關聯的 Red Hat Linux 更新套件中驗證 Dell 的身分。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
03f118a21ab6f593e6261d71cb6a5c5a
SHA1:
7cc73e17bec87ac0bad29bd72e2a9996ed94940d
SHA-256:
b3b16685cb3e808a6a7b322f434ebd8aea3d55dfe8dcb133b33245a13150ae67

檔案格式: 適用於 64 位元機器的自動解壓縮檔案
檔案名稱: M640-010307.efi
檔案大小: 17.79 MB
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
此檔案內含可從 EFI Shell 或 EFI Boot Manager執行的壓縮內容。將檔案下載到抽取式媒體裝置的 EFI 分割區。插入抽取式媒體,然後將系統重新開機,並透過 EFI Shell 或 EFI Boot Manager 執行程式。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
e0ae76d8d01ec36df9bb781848d3987d
SHA1:
fad10404edd41d0941110153238af01f2093f62f
SHA-256:
0ca3622a7aee6b6e763cf2e09b75b9c2c4ce4fc50926247e7716e184f1a1fc74

檔案格式: 封存的 PDF 檔案提供客戶說明及程序資訊
檔案名稱: M640_BIOS.1.3.7_RN.pdf
檔案大小: 218.94 KB
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
此格式包含 PDF 檔案的封存,可用來向客戶提供說明及程序性資訊。請務必先安裝 Adobe Acrobat Reader 以檢視此封存中的檔案。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
8e07001e602387b9cb25fdeb083e5a2b
SHA1:
d908a962543617361d7c455d21c07714a5e4c3de
SHA-256:
440c5639fa76713d426fe1bc6279953406f1d7d958d042ecaea16bce25be7b20

檔案格式: 適用於 Red Hat Linux 的更新套件
檔案名稱: BIOS_XRN29_LN_1.3.7.BIN
檔案大小: 26.49 MB
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
適用於 Linux 的 Dell 更新套件可做為獨立的應用程式,確保符合特定的驗證條件,然後套用更新。
注意:適用於 Linux 的更新套件為開放原始碼套件。請參閱適用於 Linux 的 Dell 更新套件的「讀我」檔案,瞭解詳情。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
7fff284393b683fbaa4421c7e03740ec
SHA1:
b2eee62f0453c604511445c1b14d5804b6ebb71c
SHA-256:
d6298e62e824ad8f8987bea9e3884649207234f991c0befb28e375edc0ab9389

當您開始下載,即表示您接受 Dell 軟體授權協定 (英文版) 的條款。

其他詳細資料

顯示全部 | 隱藏全部
An Intel Management Engine related issue that caused the BIOS update to fail is resolved in this BIOS 1.3.7 version.
- This included remedy becomes effective only after the device is updated with this BIOS 1.3.7 version.
Warning: Running an iDRAC RACADM power cycle command while running an operating system causes an ungraceful shutdown.
- To work around this issue, AC power cycle the system or run the iDRAC RACADM power cycle command before updating the BIOS.
- The first attempt to upgrade to this 1.3.7 version will fail, but the second attempt will pass if done within 24 days after the first attempt.
- For more information about this issue and safely working around this issue, see:
PSQN SLN 309027 here: http://www.dell.com/support/article/us/en/04/SLN309027
Intel HSD125807 here:
https://www.intel.com/content/dam/www/program/design/us/en/documents/hsd125807-hmrfpo-timeout-ta-337128.pdf?asset=16254
PowerEdge M640/FC640/M640-VRTX BIOS
Dell EMC Update Package Instructions for EFI
Download
1. Click the "Download Now" link to download the file.
2. If the Export Compliance Disclaimer window appears, click the "I agree" link if you accept the agreement.
3. When the File Download window appears, click "Save" to save the file to your hard drive.
Installation
You can update the BIOS using a UEFI shell bootable media, such as a USB key.
1. Copy the file to the bootable device with UEFI shell.
2. Boot the system to UEFI shell by using the bootable device.
3. Run the executable (.efi) under the UEFI shell. Follow the instructions provided by the flash utility.

You can also load this executable directly from BIOS Boot Manager without a UEFI shell bootable media.
1. Copy the file to a USB device
2. Plug in the USB device and press F11 during POST to enter BIOS Boot Manager
3. Navigate to the System Utilities menu and select BIOS Update File Explorer
4. Select the USB device and navigate through the directory contents to find the executable (.efi)
5. Launch the executable and follow the instructions provided by the flash utility.
--------------------------------------------------------------------------------
Dell EMC Update Package Instructions for Linux DUP:
Download
1. Click the "Download Now" link to download the file.
2. When the File Download window appears, click "Save" to save the file to your hard drive.
Installation
1. Read over the release information presented by executing the "./[model]_BIOS_LX_[revision].BIN --version" command from the shell.
2. Download and install any prerequisites identified in the above step before proceeding.
3. Install any necessary Embedded Systems Management firmware prior to this BIOS update.
4. Run the update by executing "./[model]_BIOS_LX_[version].BIN" from the shell.
5. Follow the remaining prompts to perform the update.
-----------------------------------------------------
Dell EMC Update Package Instructions for Windows Dup:
Download
1. Click the "Download Now" link to download the file.
2. When the File Download window appears, click "Save" to save the file to your hard drive.
Installation
1. Browse to the location where you downloaded the file and double-click the new file.
2. Read over the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window before proceeding.
4. Install any necessary Embedded Systems Management firmware prior to this BIOS update.
5. Click the Install button.
6. Follow the remaining prompts to perform the update.
-----------------------------------------------------
GnuPG Signature of Dell EMC Update Package Instructions:
Download
1. Click the "Download Now" link to download the file.
2. When the "File Download" window appears, click "Save" to save the file to your hard drive.
Installation
1. Import the Dell EMC public key. (You only need to do once on your system.)
2. Verify the Dell EMC Update Package by using its signature file, [model]_BIOS_LX_[version].BIN.sign

需要 BIOS 問題的協助嗎?

請在 Dell 的 BIOS 故障診斷和使用指南中尋找解決方案。

驅動程式說明與教學課程