請勿在更新 BIOS 時將電腦關機或拔除電源,電腦可能因此受損。更新期間,電腦將重新啟動,並且會暫時顯示黑色畫面。

更新前,請閱讀以下所述的安裝說明與重要資訊。

Dell Server Power Edge C6320P BIOS version 2.0.5

需要重新啟動 已自動安裝 此檔案會在最近更新時自動安裝。如果您遇到任何問題,可以手動下載並重新安裝。
此頁面的內容可能經過電腦自動翻譯。若要提供意見回饋,請填寫頁面底部的表單。
This release contains BIOS firmware version 2.0.5 for Dell PowerEdge C6320P. The release contains new Intel Xeon Processor Scalable Family Processor Microcode to address CVE-2017-5715; CVE-2017-5753 and CVE-2017-5754 do not require a microcode update.
建議

檢查相容性

請輸入產品的詳細資料以檢視系統的最新驅動程式資訊

輸入您的 Dell 產品服務編號或型號

想要尋找您的產品嗎?請輸入產品識別碼。 告訴我怎麼做

此驅動程式不相容

此驅動程式不適用於選取的產品。請選擇其他產品,以重新輸入適用於此驅動程式的產品詳細資料,或前往產品支援頁面,檢視其他產品的所有驅動程式。

尋找更多更新。使用 SupportAssist 為您的裝置尋找所有最新的驅動程式更新。

修復及強化

Fixes
- None for this release.

Enhancements
- Update the Intel processor microcode to address CVE-2017-5715 (http://www.cve.mitre.org/cgi-bin/cvename.cgi?name=2017-5715).
- Updated the Intel Xeon Phi(TM) processor Microcode to version 0x1B6.
- Updated the Intel Xeon Phi(TM) DL processor Microcode to version 0x018.
- CVE-2017-5753 and CVE-2017-5754 are addressed by Operating System and Hypervisor updates, please see information at http://www.dell.com/support/article/SLN308588.
閱讀更多

繁體中文版

2.0.5, 2.0.5

發佈日期

09 2月 2018

下載類型

系統 BIOS

類別

BIOS

重要性

緊急
Dell Technologies 強烈建議儘快套用此重要更新。此更新包含的重大錯誤修正和變更,可改善 Dell 系統功能、可靠性及穩定性。其也可能包含安全性修正和其他增強功能。
可用的格式 檢視重要資訊

檔案格式: 適用於 MS Windows (64 位元) 的更新套件。
檔案名稱: C6320P_BIOS_R95GJ_WN64_2.0.5.EXE
檔案大小: 17.9 MB
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
如果 Dell 更新套件為原生 Microsoft Windows 64 位元格式,則不需要在 Microsoft Windows Server 安裝 Microsoft WOW64。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
18c54c1d26953475d088279d63f69317
SHA1:
5bbeb2049561b75fa3f94ac7fa8327b21721e053
SHA-256:
68422e78bc53077ac99b524b31a27e70d660b099e001a4e789eb8a1e98961079

檔案格式: 包含密碼編譯簽章的 GnuPG 檔案
檔案名稱: C6320P_BIOS_R95GJ_LN_2.0.5.BIN.sign
檔案大小: 226 Bytes
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
您可以使用適用於 Red Hat Linux 更新套件的 GnuPG 簽章,在相關聯的 Red Hat Linux 更新套件中驗證 Dell 的身分。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
1b6277c401dfd51e452fe2d29debc10c
SHA1:
7227c4e377942c86cb4a8e377b88aa757fd3a79f
SHA-256:
2e4dbca723643ab72e70b50b00a8747b066184513a911ca46ca7d3471b0d8e44

檔案格式: 適用於 64 位元機器的自動解壓縮檔案
檔案名稱: C6320p-020005.efi
檔案大小: 5.46 MB
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
此檔案內含可從 EFI Shell 或 EFI Boot Manager執行的壓縮內容。將檔案下載到抽取式媒體裝置的 EFI 分割區。插入抽取式媒體,然後將系統重新開機,並透過 EFI Shell 或 EFI Boot Manager 執行程式。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
ea7658e29307d7b27ecfde58659be40c
SHA1:
6d8d2bbd32b9740b7c180e2253c91bfe0f0fa262
SHA-256:
ad13f217b12f0e5fee1491be419b5414054f92d26e87e5f6c5cd3054fbc5201d

檔案格式: 封存的 PDF 檔案提供客戶說明及程序資訊
檔案名稱: C6320p_BIOS_2.0.5_Release_Note.pdf
檔案大小: 109.19 KB
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
此格式包含 PDF 檔案的封存,可用來向客戶提供說明及程序性資訊。請務必先安裝 Adobe Acrobat Reader 以檢視此封存中的檔案。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
084ad2cbc934b165b41158a533f1f3cc
SHA1:
7d90cad2d592b0a02dde60b995ebaba0a3c42e65
SHA-256:
8cd52ca39d326e010d10c2577d51a624cc36d0eef20c54cb726b0460332bd5b0

檔案格式: 適用於 MS Windows (32 位元) 的更新套件
檔案名稱: C6320P_BIOS_R95GJ_WN32_2.0.5.EXE
檔案大小: 13.02 MB
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
Microsoft Windows 32 位元格式的 Dell 更新套件 (DUP) 經過精心設計,可在 Microsoft Windows 64 位元作業系統上執行。Microsoft Windows 64 位元格式的 Dell 更新套件 (DUP) 只能在 Microsoft Windows 64 位元作業系統上執行。選擇裝置驅動程式更新時,請務必選擇適用您作業系統的更新。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
3ed97f78f95284453b9d32d66d672b43
SHA1:
bfa478400f47d1a7fa2b45bd332fb2ec44771f92
SHA-256:
3016027e82c18dc911aa9cebc8372cf5404570a1e9ccf59885b1576feefb8c84

檔案格式: 適用於 Red Hat Linux 的更新套件
檔案名稱: C6320P_BIOS_R95GJ_LN_2.0.5.BIN
檔案大小: 14.47 MB
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
適用於 Linux 的 Dell 更新套件可做為獨立的應用程式,確保符合特定的驗證條件,然後套用更新。
注意:適用於 Linux 的更新套件為開放原始碼套件。請參閱適用於 Linux 的 Dell 更新套件的「讀我」檔案,瞭解詳情。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
f0502a675324cd34bf2a42263feb1a62
SHA1:
73a5d23243bdd912e9727e9a074fe9a311c98f7f
SHA-256:
1eca5a3f6f88e3652c433cf80794966572b59fb4a1a3bdd72ecceed0871082f1

當您開始下載,即表示您接受 Dell 軟體授權協定 (英文版) 的條款。

其他詳細資料

顯示全部 | 隱藏全部
Dell highly recommends applying this update as soon as possible. The update contains changes to improve the reliability and availability of your Dell system.
PowerEdge C6320P BIOS
Dell Update Package Instructions for DRMK
Download
1. Click the "Download Now" link to download the file.
2. If the Export Compliance Disclaimer window appears, click the "I agree" link if you accept the agreement.
3. When the File Download window appears, click "Save" to save the file to your hard drive.

Installation
NOTE: You must provide a DOS bootable media, such as a USB key. This executable file does not create the DOS system files.
1. Browse to the location where you downloaded the file.
2. Update the name of the file to DOS recognizable format (8.3). If you do not update the filename to 8.3 format, the filename will be truncated to 8.3 format.
3. Copy the file to the bootable device.
4. Boot the system to DOS by using the bootable device.
5. Run the executable under DOS. Follow the instructions provided by the flash utility.
--------------------------------------------------------------------------------
Dell Update Package Instructions for EFI
Download
1. Click the "Download Now" link to download the file.
2. If the Export Compliance Disclaimer window appears, click the "I agree" link if you accept the agreement.
3. When the File Download window appears, click "Save" to save the file to your hard drive.
Installation
You can update the BIOS using a UEFI shell bootable media, such as a USB key.
1. Copy the file to the bootable device with UEFI shell.
2. Boot the system to UEFI shell by using the bootable device.
3. Run the executable (.efi) under the UEFI shell. Follow the instructions provided by the flash utility.

You can also load this executable directly from BIOS Boot Manager without a UEFI shell bootable media.
1. Copy the file to a USB device
2. Plug in the USB device and press F11 during POST to enter BIOS Boot Manager
3. Navigate to the System Utilities menu and select BIOS Update File Explorer
4. Select the USB device and navigate through the directory contents to find the executable (.efi)
5. Launch the executable and follow the instructions provided by the flash utility.
--------------------------------------------------------------------------------
Dell Update Package Instructions for Linux DUP:
Download
1. Click the "Download Now" link to download the file.
2. When the File Download window appears, click "Save" to save the file to your hard drive.
Installation
1. Read over the release information presented by executing the "./[model]_BIOS_LX_[revision].BIN --version" command from the shell.
2. Download and install any prerequisites identified in the above step before proceeding.
3. Install any necessary Embedded Systems Management firmware prior to this BIOS update.
4. Run the update by executing "./[model]_BIOS_LX_[version].BIN" from the shell.
5. Follow the remaining prompts to perform the update.
-----------------------------------------------------
Dell Update Package Instructions for Windows Dup:
Download
1. Click the "Download Now" link to download the file.
2. When the File Download window appears, click "Save" to save the file to your hard drive.
Installation
1. Browse to the location where you downloaded the file and double-click the new file.
2. Read over the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window before proceeding.
4. Install any necessary Embedded Systems Management firmware prior to this BIOS update.
5. Click the Install button.
6. Follow the remaining prompts to perform the update.
-----------------------------------------------------
GnuPG Signature of Dell Update Package Instructions:
Download
1. Click the "Download Now" link to download the file.
2. When the "File Download" window appears, click "Save" to save the file to your hard drive.
Installation
1. Import the Dell public key. (You only need to do once on your system.)
2. Verify the Dell Update Package by using its signature file, [model]_BIOS_LX_[version].BIN.sign

需要 BIOS 問題的協助嗎?

請在 Dell 的 BIOS 故障診斷和使用指南中尋找解決方案。

驅動程式說明與教學課程