Toshiba Solid State Drive Firmware Update for KXG50ZNV256G/KXG50ZNV512G/KXG50ZNV1T02

Restart required AUTO INSTALLED This file was automatically installed as part of a recent update. If you are experiencing any issues, you can manually download and reinstall.
This package contains the firmware for Toshiba KXG50ZNV256G 256 GB, KXG50ZNV512G 512 GB, and KXG50ZNV1T02 1 TB non-SED M.2 2280, Revision AADA4107. Storage firmware is a microcode that is embedded on storage devices such as hard drives or solid-state drives.
Recommended

Find the best download for your system

Please enter your product details to view the latest driver information for your system

Search support

Enter your Dell Service Tag or model

Want to look up your product? Enter a product identifier. Show me how

This driver is not compatible

This driver is not applicable for the selected product. Choose another product to re-enter your product details for this driver or visit the Product Support page to view all drivers for a different product.

Find more updates. Use SupportAssist to find all the latest driver updates for your device.

Fixes & Enhancements

Fixes:
- Fixed the issue where an error message occurs when the drive is not detected.

Enhancements:
- Improved the performance of the solid-state drive (SSD).
Read More

Version

AADA4107, A00

Release date

25 Jul 2019

Download Type

Firmware

Category

Storage

Importance

Recommended
Dell Technologies recommends applying this update during your next scheduled update cycle. The update contains changes to maintain overall system health. It ensures that the system software remains current and compatible with other system modules (firmware, BIOS, drivers, and software) and may include other new features.
Available formats View Important Information

File Format: ZipPack External
File Name: Toshiba KXG50ZNV256G_KXG50ZNV512G_KXG50ZNV1T02 7YXTM_ZPE.exe
File Size: 3.66 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
This file contains a compressed (or zipped) set of files. Download the file to a folder on your hard drive, and then run (double-click) it to unzip the set of files. Follow the instructions to complete the installation.
To ensure the integrity of your download, please verify the checksum value.
MD5:
6026855c503b8374371b2b924ad2a0f2
SHA1:
fcdf231618ab6ea3cad30a162d02dcbfb6da8db8
SHA-256:
97077e2125b00263090c6ae5662bc97cce53bac356703b26ecdae750ce4099d3

By downloading, you accept the terms of the Dell Software License Agreement.

Additional details

Show All | Hide All
Ensure that you back up your data before performing this update. Do not interrupt your system during the firmware upgrade process. If the firmware upgrade process is interrupted, the solid-state drive may not function properly.
Windows 7, 32-bit
Windows 7, 64-bit
Windows 8, 32-bit
Windows 8, 64-bit
Windows 8.1, 32-bit
Windows 8.1, 64-bit
Windows 10, 32-bit
Windows 10, 64-bit
TOSHIBA XG5 1TB PCIE NVME 2280 SSD (CLASS 40)
TOSHIBA XG5 256G PCIE NVME 2280 SSD (CLASS 40)
TOSHIBA XG5 512G PCIE NVME 2280 SSD (CLASS 40)
Note:
Ensure that you back up the data in the system and close all open applications. It is also recommended to connect the power cable when it is not a desktop and disconnect all external storage devices.

Firmware upgrade through the Windows utility

Download
1. Click Download File.
2. When download is complete, run the downloaded file to extract to your drive.
3. The file explorer opens pointing to the directory containing the download package. Take note of the path.

Upgrade Procedure
1. Close all open applications and save your work before the firmware update process.
2. Go to the location where you have downloaded the package.
3. Right-click the file that is named XG5-AADA4107-64bit and select Run as administrator to run the file with administrator privilege.
4. Review the License Agreement. If you agree with it, click I ACCEPT and then click Next >.
Tips: You can save End User License Agreement (EULA) by clicking Save EULA as Text.
5. The Welcome window is displayed with a warning message at the bottom. Read the warning message carefully and click Next > to continue.
6. A window is displayed where you can select the solid-state drive (SSD) to be updated. You can select only those SSDs that are targeted for this update on the FW Update Tool.
7. Check the box next to applicable SSDs to target. Click Next > to continue.
8. Before You Begin window is displayed at this stage. Read the instructions carefully. If complied, check the box for Yes, I did and click Next > to continue.
9. Firmware update operation is initiated automatically. Once the update completion message is displayed, click Shutdown to shut down the system.
10. Since the shutdown is initiated through FW update utility, below warning message is displayed before it shuts down.
If your system has unsaved data, save everything and close all applications respectively.
If the system does not shut down automatically, shut it down manually.

New firmware is applied when you power on the system. To confirm whether the firmware update was successful, repeat the upgrade procedure steps from 1 to 6. Present firmware version is displayed against Current Firmware.

Drivers help and tutorials