Do not turn off your computer or disconnect from the power source while updating the BIOS as this could harm your computer. During the update, your computer will restart and you may briefly see a black screen.
Before updating, please read the installation instructions and important information noted below.
Dell EMC Server PowerEdge BIOS R440/R540/T440 Version 1.3.7
Restart requiredAUTO INSTALLEDThis file was automatically installed as part of a recent update. If you are experiencing any issues, you can manually download and reinstall.
This file was automatically installed as part of a recent update. If you are experiencing any issues, you can manually download and reinstall.
This release contains new Intel Xeon Processor Scalable Family Processor Microcode to address CVE-2017-5715. CVE-2017-5753 and CVE-2017-5754 do not require a microcode update. This release fixes Intel Management Engine issue that causes first BIOS flash update attempt to fail after 24 days of server up-time. This release contains BIOS firmware version 1.3.7 for Dell EMC Server PowerEdge R440/R540/T440.
Recommended
Check compatibility
Enter your Dell Service Tag or model
Want to look up your product? Enter a product identifier.Show me how
No results found.We couldn't find anything for your search. Please modify your search to enter a service tag (B959FS3) or model (Latitude 5540) and try again.
This driver is not compatible
This driver is not applicable for the selected product. Choose another product to re-enter your product details for this driver or visit the Product Support page to view all drivers for a different product.
Sign in to Windows as an admin to use automatic scan. If your're already signed in as an admin and seeing this message, please reboot.Your system is managed by your IT admin and features might be limited.
Find more updates. Use SupportAssist to find all the latest driver updates for your device.
Fixes & Enhancements
Fixes - BIOS takes a long time to handle correctable memory errors. - Rarely, the system may stop at POST (Power-On-Self-Test) when running reboot test in the BIOS boot mode. - Several NVMe-related defects. - Resolved an Intel Management Engine related issue that caused the BIOS version update to fail (fails only when the server is kept turned on continuously for 24 days since the previous AC power cycle). See the Important notes section in this Release Notes.
Enhancements - Updated the Intel Trusted Execution Technology (Intel TXT) BIOS Authenticated Code Module (ACM) to version 1.3.4. - Updated the Intel Processor and Memory Reference Code to PLR3.1. - To address CVE-2017-5715 (http://www.cve.mitre.org/cgi-bin/cvename.cgi?name=2017-5715): - Updated the Intel Xeon Processor Scalable Family Processor Microcode to version 0x43. - CVE-2017-5753 and CVE-2017-5754 are addressed by the Operating System & Hypervisor updates. - For more information, visit http://www.dell.com/support/article/SLN308588.
Dell Technologies highly recommends applying this important update as soon as possible. The update contains critical bug fixes and changes to improve functionality, reliability, and stability of your Dell system. It may also include security fixes and other feature enhancements.
File Format:A self-extracting file for use in 64-bit machines
File Name:BIOS_J9VX2_EFI_1.3.7.efi
File Size:17.76 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
This file contains compressed content that can be executed from the EFI Shell or EFI Boot Manager. Download the file to the EFI partition on a removable media device. Insert the removable media, then reboot the system and run the program from the EFI Shell or EFI Boot Manager.
File Format:An archive of PDF files to provide help and procedural information to the customers
File Name:R440R540T440_BIOS.1.3.7_RN.pdf
File Size:226 KB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
This format consists of an archive of PDF files used to provide help and procedural information to the customer. It is necessary to install the Adobe Acrobat Reader first to view the files in this archive.
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages for Linux can be used as stand-alone applications that ensure that specific validation criteria are met, then apply an update. Note: Update Packages for Linux are open source. See the Dell Update Packages for Linux Readme for details.
An Intel Management Engine related issue that caused the BIOS update to fail is resolved in this BIOS 1.3.7 version. - This included remedy becomes effective only after the device is updated with this BIOS 1.3.7 version. Warning: Running an iDRAC RACADM power cycle command while running an operating system causes an ungraceful shutdown. - To work around this issue, AC power cycle the system or run the iDRAC RACADM power cycle command before updating the BIOS. - The first attempt to upgrade to this 1.3.7 version will fail, but the second attempt will pass if done within 24 days after the first attempt. - For more information about this issue and safely working around this issue, see: PSQN SLN 309027 here: http://www.dell.com/support/article/us/en/04/SLN309027 Intel HSD125807 here: https://www.intel.com/content/dam/www/program/design/us/en/documents/hsd125807-hmrfpo-timeout-ta-337128.pdf?asset=16254
Dell EMC Update Package Instructions for EFI Download 1. Click the "Download Now" link to download the file. 2. If the Export Compliance Disclaimer window appears, click the "I agree" link if you accept the agreement. 3. When the File Download window appears, click "Save" to save the file to your hard drive. Installation You can update the BIOS using a UEFI shell bootable media, such as a USB key. 1. Copy the file to the bootable device with UEFI shell. 2. Boot the system to UEFI shell by using the bootable device. 3. Run the executable (.efi) under the UEFI shell. Follow the instructions provided by the flash utility.
You can also load this executable directly from BIOS Boot Manager without a UEFI shell bootable media. 1. Copy the file to a USB device 2. Plug in the USB device and press F11 during POST to enter BIOS Boot Manager 3. Navigate to the System Utilities menu and select BIOS Update File Explorer 4. Select the USB device and navigate through the directory contents to find the executable (.efi) 5. Launch the executable and follow the instructions provided by the flash utility. ---------------------------------------------------------------------- Dell EMC Update Package Instructions for Linux DUP: Download 1. Click the "Download Now" link to download the file. 2. When the File Download window appears, click "Save" to save the file to your hard drive. Installation 1. Read over the release information presented by executing the "./[model]_BIOS_LX_[revision].BIN --version" command from the shell. 2. Download and install any prerequisites identified in the above step before proceeding. 3. Install any necessary Embedded Systems Management firmware prior to this BIOS update. 4. Run the update by executing "./[model]_BIOS_LX_[version].BIN" from the shell. 5. Follow the remaining prompts to perform the update. ---------------------------------------------------------------------- Dell EMC Update Package Instructions for Windows Dup: Download 1. Click the "Download Now" link to download the file. 2. When the File Download window appears, click "Save" to save the file to your hard drive. Installation 1. Browse to the location where you downloaded the file and double-click the new file. 2. Read over the release information presented in the dialog window. 3. Download and install any prerequisites identified in the dialog window before proceeding. 4. Install any necessary Embedded Systems Management firmware prior to this BIOS update. 5. Click the Install button. 6. Follow the remaining prompts to perform the update. ---------------------------------------------------------------------- GnuPG Signature of Dell EMC Update Package Instructions: Download 1. Click the "Download Now" link to download the file. 2. When the "File Download" window appears, click "Save" to save the file to your hard drive. Installation 1. Import the Dell EMC public key. (You only need to do once on your system.) 2. Verify the Dell EMC Update Package by using its signature file, [model]_BIOS_LX_[version].BIN.sign
Need help with BIOS issues?
Find a solution in Dell's BIOS troubleshooting and usage guide.