PowerStore Alerts: Drive Wear-Level Alerts

Summary: The article provides solutions when facing different drive endurance levels. PowerStore

This article may have been automatically translated. If you have any feedback regarding its quality, please let us know using the form at the bottom of this page.

Article Content


Symptoms

When Dell PowerStore encounters a problem, an error alert is generated to help identify the issue. This article explains the different possible causes and the relevant solutions for these error alerts. If your problem is not resolved despite the solution that is provided, check the technical support contact options.
 
SLN317247_en_US__1icon Note: Cannot find the information that you need? Let us know using the feedback form at the bottom of this article.
 
 
Alert ID XMS_SSD_ENDURANCE_REMAINING_LIMITED
Alert Text Wear level (endurance) of the drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot) is low. The remaining wear level for this drive is %(percent_endurance_remaining).
Error Code 0x00306C02
Cause This alert is raised when the drive's remaining endurance is at or below 5%. Drive continues to function as designed.
Resolution No immediate user action is needed, but drive replacement will be needed soon. Contact technical support for further assistance.
 
 
Alert ID XMS_SSD_ENDURANCE_REMAINING_VERY_LIMITED
Alert Text Wear level (endurance) of the drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot) is very low and has reached a critical level. The remaining wear level for this drive is %(percent_endurance_remaining).
Error Code 0x00306C03
Cause This alert is raised when the drive's remaining endurance is at or below 2%. Drive continues to function as designed.
Resolution No immediate user action is needed, but drive replacement will be needed soon. Contact technical support for further assistance.
 

 
Alert ID XMS_SSD_ENDURANCE_REMAINING_NO_REMAINING
Alert Text Drive endurance level for bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot) is exhausted. The remaining wear level for this drive is %(percent_endurance_remaining).
Error Code 0x00306C04
Cause This alert is raised when the drive's remaining endurance has reached its reported limit. The drive may continue to function as designed. 
Resolution Drive should be replaced before I/O Errors and/or drive failure occurs. Contact technical support for further assistance.

Cause

 