Diagnostic tools for advanced troubleshooting on PowerEdge servers

Summary: In this article, we want to show you several ways to run diagnostics on your server to determine the source of the error. Many tools are available depending on the situation and whether the server can be taken offline or not. ...

This article may have been automatically translated. If you have any feedback regarding its quality, please let us know using the form at the bottom of this page.

Article Content


Symptoms

Not required

Cause

Not required

Resolution

In this article, we want to show you several ways to run diagnostics on your server to determine the source of the error. Many tools are available depending on the situation and whether the server can be taken offline or not.


Tools \ PowerEdge Server Generation

SLN292190_de__1Spacer15x15G9 SLN292190_de__1Spacer15x15

SLN292190_de__1Spacer15x15G10SLN292190_de__1Spacer15x15

SLN292190_de__1Spacer15x15G11SLN292190_de__1Spacer15x15

SLN292190_de__1Spacer15x15G12SLN292190_de__1Spacer15x15

SLN292190_de__1Spacer15x15G13SLN292190_de__1Spacer15x15

Dell Online Diagnostics (tests all hardware components)

SLN292190_de__1Spacer15x15Yes

SLN292190_de__1Spacer15x15Yes

SLN292190_de__1Spacer15x15Yes

SLN292190_de__1Spacer15x15Yes

SLN292190_de__1Spacer15x15Yes

Built-in hardware diagnostics (tests all hardware components)

SLN292190_de__1Spacer15x15No

SLN292190_de__1Spacer15x15No

SLN292190_de__1Spacer15x15Yes

SLN292190_de__1Spacer15x15Yes

SLN292190_de__1Spacer15x15Yes

Intel Processor  Diagnostic Tool(measures CPU performance)

SLN292190_de__1Spacer15x15Yes

SLN292190_de__1Spacer15x15Yes

SLN292190_de__1Spacer15x15Yes

SLN292190_de__1Spacer15x15Yes

SLN292190_de__1Spacer15x15Yes

IOmeter (measures I/O performance)

SLN292190_de__1Spacer15x15Yes

SLN292190_de__1Spacer15x15Yes

SLN292190_de__1Spacer15x15Yes

SLN292190_de__1Spacer15x15Yes

SLN292190_de__1Spacer15x15Yes

For more information on collecting logs on servers, refer to this article 129295, Collecting Advanced Troubleshooting Logs on PowerEdge Servers.


Click the tool you are interested in:

  • Tests all hardware components
  • Works on Microsoft Windows and various Linux versions.
  • Does not work on VMware ESX or Citrix XenServer.
  • No server reboot required.
  • The results can be saved.
SLN292190_de__36icon Note: Does not work with the S300 RAID controller.

  • Tests all hardware components
  • Available on servers since PowerEdge server generation 11 (except T110!)
  • Is a feature of lifecycle controller.
  • A reboot is required.
  • The results cannot be saved.
SLN292190_de__36icon Note: Hardware diagnostics of generation 12 and 13 servers always tests all components of the server first.

Article: How to Run Hardware Diagnostics on your PowerEdge Server


  • Is a third-party tool.
  • Measures CPU performance.
  • Works on Windows without rebooting the system.
  • Bootable Linux version is available.
  • The results can be saved.

Article: How to run a diagnostics on the processor when the system is running slowly


  • Is a third-party tool.
  • Measures I/O performance.
  • Works on Windows and Linux.
  • The results can be saved.

Article: How to test performance on PowerEdge servers with Iometer


SLN292190_de__36icon Note: If these tools have been used to diagnose the cause of the issue, a report is typically displayed that can be saved for analysis. It is important to note where the report was saved.
 