Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Event and Error Message Reference Guide For 13th Generation Dell PowerEdge Servers Version 1.3

PDF

PWR Event Messages

PWR8536

Message
Server Performance Over Power Redundancy is enabled.
Detailed Description
Server Performance Over Power Redundancy is enabled.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR0100

Message
The power button was pressed.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR0100

Message
The power button was pressed.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR0101

Message
The power button was released.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR0102

Message
The sleep button was pressed.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR0103

Message
The sleep button was released.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR0104

Message
The reset button was pressed.
Detailed Description
The system will reset.
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR0105

Message
The reset button was released.
Detailed Description
The system will reset.
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR0106

Message
The arg1 is latched.
Arguments
arg1 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR0107

Message
The arg1 is unlatched.
Arguments
arg1 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR0108

Message
The arg1 service was requested.
Arguments
arg1 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR0109

Message
The arg1 service has completed.
Arguments
arg1 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR1000

Message
The system performance restored.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
Trap/EventID
2275
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PWR1001

Message
The system performance degraded.
Detailed Description
To avoid shutdown, system performance has been degraded.
Recommended Response Action
Review system configuration and power consumption.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
Trap/EventID
2274
LCD Message
System performance degraded. Check PSUs and system configuration
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PWR1002

Message
The system performance degraded because of thermal protection.
Detailed Description
To avoid shutdown, system performance has been degraded.
Recommended Response Action
Review system configuration and system logs for thermal or environmental failures and warnings.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
Trap/EventID
2274
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PWR1003

Message
The system performance degraded because cooling capacity has changed.
Detailed Description
To avoid shutdown, system performance has been degraded.
Recommended Response Action
If unintended, review system configuration changes and thermal policy.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
Trap/EventID
2274
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PWR1004

Message
The system performance degraded because power capacity has changed.
Detailed Description
To avoid shutdown, system performance has been degraded.
Recommended Response Action
if unintended, review system configuration changes and power policy.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
Trap/EventID
2274
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PWR1005

Message
The system performance degraded because of user-defined power capacity has changed.
Detailed Description
To avoid exceeding the user defined capacity, system performance has been degraded.
Recommended Response Action
If unintended, review system configuration changes and power policy.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
Trap/EventID
2274
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PWR1006

Message
The system halted because system power exceeds capacity.
Detailed Description
The system may shutdown.
Recommended Response Action
Review system configuration, upgrade power supplies or reduce system power consumption.
Category
System Health (PWR = Power Usage)
Severity
Severity 1 (Critical)
Trap/EventID
2273
LCD Message
System power exceeds capacity. System halted. Contact support
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PWR1007

Message
The system performance degraded because power exceeds capacity.
Detailed Description
To avoid shutdown, system performance has been degraded.
Recommended Response Action
Review system configuration, upgrade power supplies or reduce system power consumption.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
Trap/EventID
2274
LCD Message
System power exceeds capacity. Performance degraded. Check PSU configuration
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PWR1008

Message
The system performance degraded because power draw exceeds the power threshold.
Detailed Description
To avoid shutdown, system performance has been degraded.
Recommended Response Action
Review system configuration, upgrade power supplies or reduce system power consumption.
Category
System Health (PWR = Power Usage)
Severity
Severity 1 (Critical)
Trap/EventID
2273
LCD Message
System power exceeds threshold. Performance degraded. Check PSU configuration
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PWR1009

Message
System power capacity is restored.
Detailed Description
System power capacity is restored.
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
Trap/EventID
2275
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC          
CMC              

PWR200

Message
Enabling the Max Power Conservation Mode (MPCM) feature will disable the Extended Power Performance (EPP) feature.
Detailed Description
Enabling the Max Power Conservation Mode (MPCM) feature will disable the Extended Power Performance (EPP) feature. MPCM forces servers in to a low-power and limited-performance mode, and then disables the ability to turn on additional servers.
Recommended Response Action
No response action required.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR2000

Message
The system powered up.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2001

Message
The system hard reset.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2002

Message
The system warm reset.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2003

Message
User requested a PXE boot.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2004

Message
System booted automatically into diagnostics.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2005

Message
The OS run-time software initiated a hard reset.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2006

Message
The OS run-time software initiated a warm reset.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2007

Message
System restarted.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR201

Message
Selecting the Server Based Power Management Mode option sets your power cap to a maximum value, server priorities to a default priority, and then disables the Max Power Conservation Mode. Do you want to continue?
Detailed Description
Selecting the Server Based Power Management Mode option sets your power cap to a maximum value, server priorities to a default priority, and then disables the Max Power Conservation Mode.
Recommended Response Action
No response action required.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR202

Message
Enabling the Max Power Conservation Mode (MPCM) feature forces servers in to a low-power and limited-performance mode, and then disables the ability to turn on additional servers.
Detailed Description
Enabling the Max Power Conservation Mode (MPCM) feature forces servers in to a low-power and limited-performance mode, and then disables the ability to turn on additional servers.
Recommended Response Action
No response action required.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR203

Message
Unable to set the System Input Power Cap value to less than or equal to 13300 W (45381 BTU/h), because the Extended Power Performance feature is enabled.
Detailed Description
The System Input Power Cap value cannot be set to less than or equal to 13300 W, because the Extended Power Performance feature is enabled.
Recommended Response Action
Enter a Power cap value greater than 13300 W, and then retry the operation.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR204

Message
Object value is successfully modified. Max Power Conservation Mode will deactivate the Extended Power Performance feature.
Detailed Description
Object value is successfully modified. Max Power Conservation Mode will deactivate the Extended Power Performance feature.
Recommended Response Action
No response action required.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR205

Message
The Server Performance Over Power Redundancy (SPOPR) feature cannot be enabled because the Extended Power Performance is enabled.
Detailed Description
The Server Performance Over Power Redundancy (SPOPR) feature cannot be enabled because the Extended Power Performance is enabled.
Recommended Response Action
Disable Extended Power Performance and retry the operation.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR206

Message
The Server Based Power Management (SBPM) feature cannot be enabled because the Extended Power Performance mode is enabled.
Detailed Description
The Server Based Power Management (SBPM) feature cannot be enabled because the Extended Power Performance mode is enabled.
Recommended Response Action
Disable Extended Power Performance and retry the operation.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR207

Message
The Dynamic Power Supply Engagement (DPSE) feature cannot be enabled because the Extended Power Performance mode is enabled.
Detailed Description
The Dynamic Power Supply Engagement (DPSE) feature cannot be enabled because the Extended Power Performance mode is enabled.
Recommended Response Action
Disable Extended Power Performance and retry the operation.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR209

Message
Unable to change the redundancy policy to either Power Supply Redundancy or No Redundancy because the Extended Power Performance is enabled.
Detailed Description
The redundancy policy cannot be changed to either Power Supply Redundancy or No Redundancy because the Extended Power Performance is enabled.
Recommended Response Action
Disable Extended Power Performance and retry the operation.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR210

Message
The redundancy policy cannot be changed to either Power Supply Redundancy or No Redundancy because the Extended Power Performance is enabled.
Detailed Description
The redundancy policy cannot be changed to either Power Supply Redundancy or No Redundancy because the Extended Power Performance is enabled.
Recommended Response Action
No response action required.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR211

Message
Unable to set the Fresh Air (FA) mode because the Extended Power Performance (EPP) feature is enabled.
Detailed Description
The Fresh Air (FA) mode cannot be set because the Extended Power Performance (EPP) feature is enabled.
Recommended Response Action
No response action required.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR213

Message
Cannot enable the Extended Power Performance (EPP) mode because the Max Power Conservation Mode (MPCM) is enabled.
Detailed Description
Cannot enable the Extended Power Performance (EPP) mode because the Max Power Conservation Mode (MPCM) is enabled.
Recommended Response Action
Disable the Max Power Conservation Mode and retry the operation.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR214

Message
Cannot enable the Extended Power Performance (EPP) mode because Dynamic Power Supply Engagement (DPSE) is enabled.
Detailed Description
Cannot enable the Extended Power Performance (EPP) mode because Dynamic Power Supply Engagement (DPSE) is enabled.
Recommended Response Action
Disable Dynamic Power Supply Engagement (DPSE) and retry the operation.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR216

Message
Unable to enable Extended Power Performance, because Redundancy Policy is set to Grid Redundancy or No Redundancy.
Detailed Description
Unable to enable Extended Power Performance, because redundancy policy is set to Grid Redundancy or No Redundancy.
Recommended Response Action
Configure Redundancy Policy to Power Supply Redundancy and retry the operation. Using the CMC Web GUI, click Power > Configuration. From the Redundancy Policy drop-down menu, select Power Supply Redundancy.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR218

Message
Cannot enable the Extended Power Performance (EPP) feature because the Fresh Air (FA) mode is enabled.
Detailed Description
Cannot enable the Extended Power Performance (EPP) the feature because the Fresh Air (FA) mode is enabled.
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR219

Message
The Extended Power Performance (EPP) feature cannot be enabled because the PSU in slot arg1 is not a 3000 W PSU.
Arguments
arg1 = slot number
Detailed Description
The Extended Power Performance (EPP) feature cannot be enabled because PSU in the slot identified in the message is not a 3000 W PSU.
Recommended Response Action
In order to use the Extended Power Performance (EPP) feature, replace the PSU identified in the message with a 3000 W PSU.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR220

Message
The Extended Power Performance (EPP) feature cannot be enabled because slot arg1 is empty.
Arguments
arg1 = slot number
Detailed Description
The Extended Power Performance (EPP) feature cannot be enabled because the slot identified in the message is empty.
Recommended Response Action
Insert an appropriate PSU in the slot identified in the message and retry the operation.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR2200

Message
The system is in the ON state.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2201

Message
The system is sleeping with system hardware and processor context maintained.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2202

Message
The system is sleeping with lost processor context.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2203

Message
The system is sleeping with system hardware and processor context lost.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2204

Message
The system is in a non-volatile sleep state.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2205

Message
The system is in a soft-off state.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2207

Message
The system is in a mechanical off state.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2208

Message
The system is in a sleep state.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2209

Message
The system is in an undermined sleep state.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR221

Message
The Extended Power Performance (EPP) feature is already disabled.
Detailed Description
The Extended Power Performance (EPP) feature is already disabled.
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR2210

Message
The system was forced into a soft-off state.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2211

Message
The system is in legacy ON state.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2212

Message
The system is in legacy OFF state.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR222

Message
The Extended Power Performance (EPP) feature is already enabled.
Detailed Description
The Extended Power Performance (EPP) feature is already enabled.
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR223

Message
Cannot perform a 110V AC operation because the Extended Power Performance (EPP) feature is enabled.
Detailed Description
Cannot perform a 110V AC operation because the Extended Power Performance (EPP) feature is enabled.
Recommended Response Action
Disable the Extended Power Performance (EPP) feature and retry the operation.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR2250

Message
Unable to turn on the server because the chassis infrastructure not ready.
Detailed Description
The server did not turn on because the chassis infrastructure is not ready. The chassis infrastructure includes: PCIe subsystem, storage components, and the chassis management controller.
Recommended Response Action
Check the status of the chassis infrastructure in the CMC Web or RACADM interface. Wait until the chassis infrastructure components are fully turned on.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2251

Message
Unable to turn on the server because the chassis cover is open.
Detailed Description
The server did not turn on because the chassis cover is open.
Recommended Response Action
Close the chassis cover and retry the operation.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2252

Message
Unable to turn on the server because an NDC or Mezzanine card is incompatible with the I/O Module or PCIe subsystem.
Detailed Description
The server did not turn on because an NDC or Mezzanine card is incompatible with the I/O Module or PCIe subsystem.
Recommended Response Action
Check the release notes for the product and make sure to install compatible components in the server.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2253

Message
Unable to turn on the server because a PCIe card or Mezzanine card is not installed.
Detailed Description
The server did not turn on because a PCIe card or Mezzanine card is not installed.
Recommended Response Action
Install a PCI or Mezzanine card in the appropriate slot and retry the operation.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2254

Message
The use of 110V is unacknowledged and the chassis cannot grant power on permission to the server.
Detailed Description
The use of 110V is unacknowledged for the chassis and the chassis cannot grant power on permission to the server.
Recommended Response Action
Check for unacknowledged use of 110V and change to acknowledged. Using the Chassis Management Controller (CMC) web interface, select Chassis Overview>Power>Configuration and then check the 110V Acknowledge field. Retry the operation to turn on the server.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2255

Message
The Chassis Management Controller (CMC) is configured in Max Power Conservation Mode and is unable to grant power on permission to the server.
Detailed Description
The Chassis Management Controller (CMC) is configured in Max Power Conservation Mode and is unable to grant power on permission to the server.
Recommended Response Action
Disable the Max Power Conservation Mode on the chassis and retry the operation. Using the Chassis Management Controller (CMC) web interface, select Chassis Overview>Power>Configuration and then uncheck the Max Power Conservation Mode field.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2256

Message
Unable to allocate power for servers to turn on because the Chassis Management Controller (CMC) is initializing chassis infrastructure components.
Detailed Description
The chassis infrastructure components are being initialized and are not ready to grant power on permission to the servers.
Recommended Response Action
Wait until the chassis infrastructure has been initialized and then retry the operation. To check that the infrastructure is initialized, using the RACADM command line utility run the command "racadm getmodinfo" and check that the "pwrstate" field is on for the chassis component.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2257

Message
The target power allocation override is arg1 . The target power allocation (AC) is arg2 Watts.
Arguments
arg1 = override state, arg2 = target power
Detailed Description
The target power allocation override has been enabled or disabled as identified in the message.
Recommended Response Action
No response action required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2258

Message
The Power Supply Unit (PSU) hotspare thresholds were modified. Wake Threshold: arg1 %, Sleep Threshold: arg2 %.
Arguments
arg1 = wake threshold, arg2 = sleep threshold
Detailed Description
The Power Supply Unit (PSU) hotspare thresholds were modified to the Wake Threshold and Sleep Threshold identified in the message.
Recommended Response Action
No response action required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2260

Message
The Intel Management Engine is unresponsive and the server thermal failsafe state is activated.
Detailed Description
The iDRAC experienced an IPMB communication issue with the Intel Management Engine and was not able to recover IPMB communications. The server thermal failsafe state is activated.
Recommended Response Action
Disconnect power from the server and reconnect power. Turn on the server. If the issue persists, contact your service provider.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2261

Message
Current Monitor initialization issue observed, IMON Revision arg1 , CPLD IMON MFR Revision arg2 .
Arguments
arg1 = current monitor revision number, arg2 = CPLD revision number
Detailed Description
The iDRAC experienced an issue initializing the Current Monitor. The system motherboard may need replacement.
Recommended Response Action
Contact your service provider.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2262

Message
The Intel Management Engine has reported an internal system error.
Detailed Description
The Intel Management Engine is unable to utilize the PECI over DMI facility.
Recommended Response Action
Look for the PWR2264 "normal system operation" message in the Lifecycle Log after the PWR2262 entry. It may take 30 seconds for the message to be logged. If the PWR2264 message does not appear, do the following: Disconnect power from the server and reconnect power. Turn on the server. If the issue persists, contact your service provider.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2263

Message
User ignored Power Supply Oversubscription Warning.
Detailed Description
User continued after receiving power supplyoversubscription warning (F1/F2).
Recommended Response Action
No response action required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2264

Message
The Intel Management Engine has reported normal system operation.
Detailed Description
The Intel Management Engine has recovered the ability to utilize the PECI over DMI facility.
Recommended Response Action
If the PWR2262 "internal system error" was logged within the previous 30 seconds, ignore the message. No response action required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2400

Message
Power management firmware unable to maintain power limit
Detailed Description
The power management firmware cannot reduce power consumption to meet configuration or user defined settings,
Recommended Response Action
"1) Review system power policy. 2) Check system event logs for thermal or power related exceptions."
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2401

Message
Power management firmware initialization error
Detailed Description
The iDRAC controller detected that the power management firmware did not initialize properly. The system may operate in a performance degraded state.
Recommended Response Action
"1) Disconnect system input power, wait one minute, reconnect system input power. 2) Re-flash system BIOS. 3) Upgrade system BIOS to the latest revision."
Category
System Health (PWR = Power Usage)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2402

Message
iDRAC is unable to communicate with power management firmware.
Detailed Description
The iDRAC controller cannot communicate with the power management firmware due to an problem with the interface to the power management engine or with the power management engine itself. The system may operate in a performance degraded state.
Recommended Response Action
Check the Lifecycle Controller Log (LC Log) and make sure that there are no subsequent log entries indicating that Communication with power management firmware has been restored. If this log entry is not present then do one of the following: 1) Disconnect system input power, wait one minute, reconnect system input power. 2) Re-flash system BIOS. 3) Upgrade system BIOS to the latest revision.
Category
System Health (PWR = Power Usage)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2403

Message
iDRAC communication with power management firmware has been restored.
Detailed Description
The iDRAC controller established communication to the power management firmware. System performance will return to normal.
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2404

Message
Power supply capacity alert disabled.
Detailed Description
Power supply capacity alert disabled due to user configuration.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR3000

Message
The system is being shut down for thermal protection.
Detailed Description
To avoid system damage because of insufficient cooling, the system is being shut down.
Recommended Response Action
Review the Embedded System Management Log for thermal or environmental failures and warnings, and replace the faulty components. If the issue persists, contact your service provider.
Category
System Health (PWR = Power Usage)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR3001

Message
Detected new peak power value. Peak value (in Watts): arg1 .
Arguments
arg1 = peak value
Detailed Description
The system has detected a new peak power value.
Recommended Response Action
Make sure that the power usage corresponds to the current hardware configuration and workload.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
OMSA Event ID
5013
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC   ✔*        
CMC              

PWR8500

Message
Chassis power state updated to arg1 from arg2 .
Arguments
arg1 = new power state, arg2 = old power state
Detailed Description
The chassis power state from the configuration database and the current state are different. The current chassis power state will be updated in the configuration database. This is to insure the chassis power state will be the same if the CMC is rebooted or a CMC failover occurs. Note that the numerical value of the state is intended for technical support use.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8501

Message
Successfully set Virtual Infrastructure Device power to arg1 WDC
Arguments
arg1 = power reading
Detailed Description
Power allocation succeeded for Virtual infrastructure.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8503

Message
The current value of System Input Power Cap ( arg1 AC) is less than the upper limit ( arg2 AC).
Arguments
arg1 = power value, arg2 = power value
Detailed Description
This Information is provided to enable checking whether the powercap is lower than the maximum supported powercap limit.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8504

Message
Chassis power button is pressed, but the button is disabled.
Detailed Description
The chassis power button press is detected but the button has been disabled.
Recommended Response Action
The chassis power button is disabled. To enable the chassis power button use the CMC RACADM command line interface, CMC Web interface. Using the command line, enter "racadm config -g cfgChassisPower -o cfgChassisPowerButtonEnable 1". Using the Web interface, click Chassis Overview > Power > Configuration. Clear the Disable Chassis Power Button check box.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8505

Message
The Dynamic Power Supply Engagement feature was not successfully enabled.
Detailed Description
The Dynamic Power Supply Engagement feature was not successfully enabled.
Recommended Response Action
Restart the Chassis Management Controller and retry the operation. To restart the Chassis Management Controller, using the WEB UI, go to Chassis Overview > Power > Control, select the Reset CMC option, and then click Apply.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8506

Message
Cumulative power computation (KWH) time is reset on arg1 .
Arguments
arg1 = time
Detailed Description
Resetting the power computation reading causes the log to report time at which it is reset.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8507

Message
System Input Power Cap changed from arg1 W AC to arg2 W AC.
Arguments
arg1 = previous power value, arg2 = new power value
Detailed Description
The system Input Power Cap was changed from the value to the value indicated in the message.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8508

Message
New power budget ( arg1 W AC) may permit future degradation of redundancy.
Arguments
arg1 = power value
Detailed Description
If the power budget exceeds the effective capacity for the current redundancy policy, it is possible for power allocations to grow beyond the effective capacity, which would reduce redundancy capabilities.
Recommended Response Action
No response action is required. Make sure there are enough PSUs to support redundancy at the specified power budget.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8509

Message
Unable to change the server power priority because Server Based Power Management mode is enabled.
Detailed Description
Unable to change the server power priority because Server Based Power Management mode is enabled.
Recommended Response Action
The server power priority can be changed once Server Based Power Management mode is disabled. Using the CMC Web UI, navigate to the Chassis Overview > Power > Configuration page, then uncheck the Enable Server Based Power Management checkbox. Retry the operation.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8510

Message
Unable to set chassis power property arg1 .
Arguments
arg1 = property name
Detailed Description
Unable to set the chassis power identified in the message.
Recommended Response Action
Retry the operation. If the issue persists, contact your service provider.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8511

Message
Unable to set the CHASSIS_POWER_button_disable chassis power property.
Detailed Description
Unable to set the CHASSIS_POWER_button_disable chassis power property.
Recommended Response Action
Retry the operation. If the issue persists, contact your service provider.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8512

Message
CMC rebooted, because the power configuration data could not be accessed.
Detailed Description
Power configuration data in memory cannot be accessed due to synchronization issues.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8514

Message
Unable to perform chassis power action due to insufficient privileges.
Detailed Description
The user account credentials provided for this chassis power action do not have the correct privilege. Chassis control privilege is required to perform chassis power actions.
Recommended Response Action
Retry to action with a different user account that has chassis power control privilege.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8515

Message
Unable to perform the chassis power action because the chassis is not turned on.
Detailed Description
Unable to perform the chassis power action because the chassis is not turned on.
Recommended Response Action
Turn the chassis on and retry the operation.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8516

Message
Unable to perform the chassis power action requested..
Detailed Description
Unable to perform the chassis power action requested.
Recommended Response Action
Check the tracelog for more information. If the issue persists, contact your service provider.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8517

Message
Unable to turn off chassis power.
Detailed Description
Chassis power state transition did not complete successfully. This may be due to one of the following: 1) Unable to turn off one or more servers, 2) A firmware update may be in progress.
Recommended Response Action
Check the tracelog for more information. If the issue persists, contact your service provider.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8518

Message
Unable to perform the chassis power action because the chassis is already turned on.
Detailed Description
Unable to perform the chassis power action because the chassis is already turned on.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8519

Message
Unable to perform the chassis power action because the chassis is already turned off.
Detailed Description
Unable to perform the chassis power action because the chassis is already turned off.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8520

Message
Initiated the chassis reset operation.
Detailed Description
The chassis reset operation was initiated.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8521

Message
Completed chassis reset operation.
Detailed Description
The chassis reset operation was completed.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8522

Message
Initiated chassis power cycle operation.
Detailed Description
The chassis power cycle operation was initiated.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8523

Message
Completed chassis power cycle operation.
Detailed Description
The chassis power cycle operation was completed.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8524

Message
Redundancy was lost, while Server Performance Over Power Redundancy is enabled.
Detailed Description
The redundancy was lost because the power requirement of the chassis exceeds the current redundant policy.
Recommended Response Action
No response action is required. Review the power requirements and determine if more PSUs are needed to restore redundancy.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8525

Message
110VAC Operation acknowledged.
Detailed Description
110VAC operation of PSUs is acknowledged.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8526

Message
110VAC Operation unacknowledged.
Detailed Description
110VAC operation of PSUs is unacknowledged.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8527

Message
Server slot power priorities changed - reallocating power.
Detailed Description
Server slot power priorities were changed. Power to servers is being reallocated.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8528

Message
Unable to set Max Power Conservation Mode because the Server Based Power Management mode is enabled.
Detailed Description
The Max Power Conservation Mode can be enabled only when Server Based Power Management Mode is disabled.
Recommended Response Action
The Max Power Conservation Mode can be changed when Server Based Power Management mode is disabled. Using the CMC Web UI, navigate to the Chassis Overview > Power > Configuration page, then uncheck the Enable Server Based Power Management checkbox. Retry the operation.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8529

Message
Max Power Conservation Mode is enabled.
Detailed Description
The Max Power Conservation Mode is enabled.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8530

Message
Max Power Conservation Mode is disabled.
Detailed Description
Max Power Conservation Mode is disabled.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8531

Message
Server Based Power Management Mode is enabled.
Detailed Description
Server Based Power Management Mode is enabled.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8532

Message
Server Based Power Management Mode is disabled.
Detailed Description
Server Based Power Management Mode is disabled.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8533

Message
Power cap changed from arg1 W AC to arg2 W AC.
Arguments
arg1 = power value, arg2 = power value
Detailed Description
Power cap setting was changed.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8534

Message
Unable to set Server Based Power Management Mode to enable.
Detailed Description
Unable to set Server Based Power Management Mode to enable.
Recommended Response Action
Retry the operation. If the issue persists, contact your service provider.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8535

Message
Unable to set Server Based Power Management Mode to disable.
Detailed Description
Unable to set Server Based Power Management Mode to disable.
Recommended Response Action
Retry the operation. If the issue persists, contact your service provider.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\